Why do instrument clusters malfunction?

Why do instrument clusters malfunction?

Thijs Jasink, COO at ACtronics, looks in detail at the remanufacturing process on a 2003-Renault Scenic II.

Nowadays, the chances of spotting analogue instrument panels in cars are getting slimmer. The development of modern cars keeps evolving and the instrument panels naturally need to keep up with this progress. The manufacturers may still try to make the dashboard look like its analogue, but the inputs for the gauges are all computerised.

The main reason for modernising the instrument panel is the introduction of the CAN-network. Because of this network, all the data can be sent through one single flat cable, instead of using multiple wiring harnesses throughout the car. This also makes it possible to let multiple computers access the same data at the same time without interfering.

The digital instrument panel of the 2003-Renault Scenic II is a good example of these modernised cockpits; almost all data is gathered from the CAN-network and the instrument panel has its own EEPROM (Electrically Erasable Programmable Read-Only Memory) and processor, so it can process and store all of the incoming information. But the progress that these instrument panels have made has also been their weak link when it comes to malfunctions. For example, the mileage can be corrupted very easily.

What’s causing the main malfunctions?

To be honest with you, these instrument panels tend to malfunction often. The French aren’t exactly known for building reliable car electronics and these clusters show us exactly why this reputation exists.

In this case it wasn’t hard at all to actually make the remanufactured instrument panels more reliable than the original devices. If you search the internet a little, you’ll notice very quickly that this isn’t just our opinion. Customers from all over the world are complaining a lot, not only about the poor build quality, but also about Renault’s customer service.

The problems often start with short shutdowns and the cluster constantly switching off and on again. These problems will get worse in time and, in many cases, the instrument panel will shut down permanently. Not only is this permanent shutdown really annoying, it also causes the mileage to get corrupted. This corruption is a permanent one and can only be restored by resetting the mileage with a special computer.

Another problem that we’ve noticed is the clock is resetting to 0:00 on regular occasions. This could be due to a faulty battery, but a malfunctioning instrument panel also displays this kind of malfunction. The instrument panel isn’t designed to send out data to other devices so that that’s why we never get to see any fault codes that are due to a faulty instrument panel. The malfunction is purely focussed on the cluster itself.

Most of the malfunctions described in this article are caused by weak solder joints. But we can’t just repair them all with some simple soldering as not all joints are mendable and some cracks will cause additional damage. Creating new joints and replacing devices like the processor and the EEPROM are necessary most of the time. You also can’t rule out the fact that those devices may also malfunction themselves; an EEPROM may be built to handle over 100,000 processes, but failure is always still possible.

Replacing components like processors and EEPROMs makes reprogramming inevitable. This requires special equipment and lots of knowledge. Luckily at ACtronics we’ve mastered this skill, so we can create every configuration we like: adjusting the mileage, changing the panel language and more.

Because of our own research we now know how to use and adjust the hexadecimal signals of the CAN-network in a way that allows us to control the outcome. So if an EEPROM fails, we know exactly how to repair and reprogram this.

Why do instrument clusters malfunction?

Remanufacturing: the process

It would be a lot easier to just repair the broken joints and return the item to our customer, but that isn’t the way we do business at ACtronics. Every single instrument cluster gets the full treatment, which means that every component that’s known to fail at some point will be replaced or improved.

The final check is very precise. The instrument cluster has to withstand a certain amount of pressure on both ends of the circuit board in a way it will bend. We also vary the current between 10V and 16V and, on top of that, we simulate several inputs to make sure the cluster is working properly.

Only when the device passes all these tests will we apply the big black screen again. This won’t be the original screen, but a brand new one. It’s all part of our way to show you the quality of our services: it’s not only remanufactured from the inside, but you can also see the difference on the outside.

The instrument cluster in detail

Behind the big black screen you will find a large circuit board with two displays placed on it. The large display shows you the basic functions like speed, rpm and fuel level while the small display is mainly used to show functions like time, outside temperature and radio information. Each display has its own connector. We see all kinds of signals reaching these displays. Not all signals are coming through the CAN-network yet, but this instrument panel clearly shows that the CANnetwork is getting more important every day.

Instrument panels are not only capable of receiving CAN-messages, but can also calculate, store and transmit these values. As described previously, the instrument cluster of the Renault Scenic has an EEPROM and a processor. The EEPROM does exactly what its name says: it lets the other components read, store and erase data. Some examples of this include:

1. The processor uses the EEPROM to read values – such as mileage – recalculate these values and then store them again.

2. The display uses the EEPROM to display the currently stored mileage.

Why do instrument clusters malfunction?You can imagine that a lot can go wrong when this process suddenly shuts down, right in the middle of a calculation. Data could get corrupted when an interruption takes place exactly at the moment that the processor is trying to store new data. The stored data isn’t complete and that stops the whole process, so that’s why we often see incorrect mileage numbers.

This instrument cluster doesn’t transmit information to other devices. Data, such as current speed and several engine values, is being spread already through the CANnetwork, so it simply isn’t needed to send any additional values.

Removing the cluster

This is the easy part. To remove the cluster from the dashboard, you first have to remove the plastic trim which covers the bolts. Remove the upper part of the trim first and the lower part second. Once these are removed, you can clearly see the Torx-bolts; remove these bolts one by one. You can now pull the panel out in your direction, though it’s wise to pull out the bottom first, since the panel has its connectors on the upper side.

Dealer Watch

A lot of Renault dealerships will have an instrument cluster in stock so, when a customer arrives with a defective cluster, they can replace it right away and keep the customer running in his/her own car. In the meantime the dealership is able to arrange for the customer’s original cluster to be remanufactured. The instrument cluster doesn’t need reprogramming, so exchanging is simple. When the cluster comes back from remanufacturing, the customer will then get their own device back. However, as long as the customer drives with the temporary cluster, the mileage is stored on that device.